Detailed Real -Time Status 6kVA-20kVA Online UPS Parallel Redundancy Wide INPUT Voltage Range PF 0.8 192VDC battery

6kVA-20kVA High Frequency Online UPS with 0.8 output power factor and 192VDC battery voltage.

IP/OP: 380/220VAC 50Hz/60Hz(10~20K)

APPLICATION:

Servers, Data-Center, Critical network devices, Sensitive

electronic equipment, Telecom...

DX6K-DX3120KL, adopts the double conversion online architecture ideal for resolving all issues on power supply. This state-of-the-art solution is especially designed for eliminating the power loss, extra high or low voltage of utility power, voltage sags or damped oscillation, high-voltage pulse, voltage fluctuation, surge voltage, harmonic distortion, clutter immunity, and frequency fluctuation etc., delivering safe and reliable power supply guarantee for user's load. DX6K-DX3120KL is a powerful product range with high adaptability and flexibility. Its cut-edge digital control technology of DSP (Digital Signal Processor), can greatly improve the product performance and system reliability, and deliver a compact integration with higher power density. Meanwhile, DX6K-DX3120KL is especially tailored for all customer's personalized demands to provide powerful scalable functions. The unit can be flexibly configured on user's demands.Output power factor up to 0.8 applicable to the tendency of future load evolution, and deliver higher payload capability. Total power factor up to 90% can minimize the power loss of UPS and utilization cost for user. Active power factor correction (PFC) technology allows the input power factor approaching to 1, dramatically reducing the immunity on utility grid. Wider range of input voltage tailored for China grid can be suitable to all severe environments. Excellent input frequency range makes UPS suitable to different power supply devices, i. e. Generator set.Flexible Configuration on DemandHigh Scalability: Fully meet the customer's demands. Online Intervention: Safe and online intervention without any power supply interruption to load. Emergency Power Off (EPO): UPS can be instantly shut off in case of any emergency. Parallel Kit: Realize the parallel extension and redundancy function, offer more flexibility and safety for user's power supply planning. Dust-proof Kit: Increases the dust-proof level in industrial environment. Isolating Transformer: Offer isolation protection for the user.Compact Design, Lower NoiseWith leading control technology and craftsmanship, this UPS can greatly increase the power density and reduce the footprint, therefore save more expensive space in your office environment. Additionally, its lower noise during operation can allow you a more comfort working environment.Intelligent battery managementWith its advanced intelligent charge control mode, UPS can automatically select the optimal charge mode as per the battery type and conditions, thus further maximizing the lifespan of battery bank. In addition, the system can periodically conduct the charge & discharge management for the battery bank. User also can select the battery voltage (192V or 240V) on demands. The user can query and set the proper UPS control parameters for intelligent UPS management. It may automatically identify and adapt to 50/60Hz power supply system, fulfilling the requirements in various power supply systems. Perfect failure protection and alarm function: Provide complete failure protection and clear alarm notification function in case of I/O over-voltage or under-voltage, battery over-charge or under-voltage, overload, and short circuit.High ReliabilityIts cut-edge digital control technology of DSP (Digital Signal Processor) can deliver higher quality, performance and reliability. Higher payload and overload capability, better load compatibility, and suitable for various load type. Powerful Interference immunity capability in compliance with EMC requirements of IEC61000-4, deliver your device a clean electric environment.

 Salient features

  Online Real -Time UPS Zero Transferm Time N+X Parallel Redundancy

MODELSTANDARDDX6KDX10KDX6KLDCX3115KLDX3120KL
CAPACITYVA/W6KVA/4.8KW10KVA/8KW6KVA/4.8KW15KVA/12KW20KVA/16KW
INPUTNominal Voltage220/230/240VAC380VAC
Voltage Range120-275VAC210-475VAC
Frequency Range46-64Hz: 50Hz, 60Hz auto sense
PhaseSingle phase with GroundThree phase (4 Wires+Ground)
Power Factor>=0.99>=0.95
OUTPUTVoltage220/230/240*(1±1%)VAC
Frequency50/60Hz(Adjustable)50Hz AC Mode: Follow AC Mode (AC Range 46~54Hz); Battery Mode: 50Hz(1±0.1%)60Hz AC Mode: Follow AC Mode (AC Range56~64Hz); Battery Mode: 60Hz(1±0.1%)
Wave FormPure Sine Wave
Power Factor0.8
Harmonic Distortion=<2% THD (Linear Load), =<6% THD (Non-Linear Load)
Overload CapacityNormal when load < 105%; 105%-125% for 1 min, 125%-150% for 30sec
Current Crest Ratio3:1
ConnectionsTerminal block
EfficiencyTo AC Mode88%85%
To Battery Modeup to 90%
BatteryTypeSealed free maintenance lead acid battery
Nominal DC voltageBuilt in batteries 12v7.2ah*16pcs192VDC192VDC
Quantity16pcs16pcsDepends on requested back-up timeDepends on requested back-up time
Back-up Time (Full load)>=7 min>=5 minDepends on the capacity of external battery bankDepends on the capacity of external battery bank
Recharge Time7 hours to 90%Depends on the capacity of external battery bankDepends on the capacity of external battery bank
Charge current(MAX)2.0A4.2A or 8A4.2A or 8A
Charge voltage220Vdc ± 1%
BypassAutomatic TransferOn overload and UPS failure
Before UPS Power-onDefault "ON" user adjustable to "YES"
Transfer Time                    Zero
IndicatorsLCD DisplayUPS status, I/P & O/P voltage& frequency, Battery voltage, Battery capacity, Loading, Fault code
Audible Alarm Bypass, On battery mode, Battery low, Overload, Fault
Acoustic noiseAt 1 meter distance<55dB<60dB
CommunicationsIntelligent RS232 serial portWindows 98/NT/2000/XP/2003, Linux, Sun Solaris, IBM Aix, Compaq True64, SGI IRIX, FreeBSD, HP-UX, and MAC
SNMP (Optional)Power management from SNMP manager and web browser
USB (Optional)Windows family software and Mac OS
EnvironmentalOperating Temperature0~40 °C
Operating Humidity20~90% ( Non Condensing)
WeightNet weight (kg)5767.5182035
UPS DimensionL*W*H (mm)500*248*616500*240*460570*260*717

 

 

 

 

 

 

6kVA-20kVA Online UPS with 0.8 Output Power Factor and 192VDC Battery