On-Line Double Conversion Technology,IGBT Rectifier UPS with Built in Isolation Transformer 3 phase in / 3phase out 10 to 300kVAIGBT Rectifier Real Digital Signal Processor (DSP) Controlled Built in Output Isolation Transformer Input Power Factor Correction (>0.99 ) Low Total Harmonic Distortion Level (THDi <= 4% ) and (THDv<1.5%) Wide Input Voltage Range Generator Compatible Operation Evolution and redundancy guaranteed by Parallel Systems Intelligent battery management system extends lifetime of batteries Synchronization Capability with external sources Static and Manual Bypass Communication with computers and network systems with SNMP availability Expandable battery blocks Low installation and operating costs EPO (Emergency Power Off)
MODEL | PDSP-T 33010 | PDSP-T 33015 | PDSP-T 33020 | PDSP-T 33030 | PDSP-T 33040 | PDSP-T 33060 | PDSP-T 33080 | PDSP-T 33100 | PDSP-T 33120 | PDSP-T 33160 | PDSP-T 33200 | PDSP-T 33250 | PDSP-T 33300 |
Output Power (kVA) | 10 | 15 | 20 | 30 | 40 | 60 | 80 | 100 | 120 | 160 | 200 | 250 | 300 |
Active Power (kW) | 8 | 12 | 16 | 24 | 32 | 48 | 64 | 80 | 96 | 128 | 160 | 200 | 240 |
INPUT | |
Number of phases | 3Ph + N + PE |
Nominal Voltage | 380V / 400V / 415V |
Voltage Range (100% load) | -15%~+27% |
Voltage Range (64% load) | -45%~+27% |
Voltage Range (42% load) | -64%~+27% |
Nominal Frequency (Hz) | 50 or 60 ±10% |
Input Current THD | 4% |
Input Power Factor | 0.99 |
OUTPUT | |
Output Power Factor | 0.8 |
Number of Phases | 3Ph+N+PE |
Voltage | 380V/400V/415V |
Static Voltage Regulation at %100 Linear Load ( online&battery mode) | <1% |
Voltage THD at rated linear load | <1.5% |
Crest factor | 3:1 |
Free Running Frequency (Hz) | 50 or 60 ± 0.01 % |
Overload | 125% for 10 minutes; 150% for 1 minute |
Efficiency | =>90% |
STATIC BYPASS | |
Voltage Range | 380V/400V (Ph-Ph) ±10% |
Frequency Rangefor bypass operation (Hz) | ±6% (Adjustible) |
BATTERY | |
Type | Maintenance-free lead acid batteries |
Battery Quantity (pcs) | 54 (2x27) |
Battery Protection | Deep discharge Protection with Auto Cut Off |
Battery Test | Standard (Automatic and Manual) |
COMMUNITATION | |
Interface (communication ports) | RS232 & RS422 |
Dry Contact Signals | AC Failure, Battery Under Voltage, Bypass Operation, Output Failure |
Others | EPO, Generator Interface |
PHYSICAL SPECIFICATION | |
Dimensions (WxDxH) mm | 400x780x1070 | 520x900x1300 | 635x1000x1400 | 760x1025x1685 | 960x1080x1820 | 1610x1080x1930 |
Weight (kg) | 235 | 238 | 273 | 450 | 502 | 625 | 680 | 790 | 1200 | 1290 | 1740 | 1840 |
STANDARDS | EN 62040-1-1 (safety), EN 62040-2 (EMC), EN 62040-3 (VFI-SS-111) |
Inform PDSP-T 33010 UPS (Pyramid DSP-T Series)