Welcome to ECVERY
MD series low frequency online ups(three pahse in three out)
MD series low frequency online ups(three pahse in three out)
Supplier Info
[China Supplier]
Contact Person : Ms. feng feng
Tel : 86-757-86112961
Fax : 86-757-82512690
Product Detail
online ups, power supply The double DSP control system 5.5 inch LCD screen

10KVA-80KVA online ups

MODEL

MD-TC1036L

MD-TC1536L

MD-TC2036L

MD-TC3036L

MD-TC4036L

MD-TC6036L

MD-TC8036L

Capacity

10KVA/8KW

15KVA/12KW

20KVA/16KW

30KVA/24KW

40KVA/32KW

60KVA/48KW

80KVA/64KW

Efficiency

>85%

>90%

 

Battery voltage

384VDC

 

Surrounding

Audible noise

<58dB

<63dB

Size

W×D×H(mm)

660×550×1250

780×700×1520

Weight

220/230

230/265

270/305

330/365

360/410

430/480

500/550

         

(32)

100KVA-400KVA

MODEL

MD-TC1046L

MD-TC1246L

MD-TC1536L

MD-TC2036L

MD-TC3046L

MD-TC4046L

 

Capacity

100KVA/80KW

120KVA/96KW

150KVA/120KW

200KVA/160KW

300KVA240KW

400KVA/320KW

Efficiency

>96%

>94%

 

Battery voltage

384VCD

396VCD

408VCD

 

Surrounding

Audible noise

<65dB

<68dB

Size

W×D×H(mm)

1000×900×1680

1600×980×1800

Weight

780/840

880/940

950/1010

1600/1700

2100/2200

2500/2600

        

 

 

 

 

Input

 

Voltage

380V/400V/415V±20%Three phase and four wire

 

Frequency

50 Hz±10%/60Hz±10%

 

 

 

 

Output

Voltage

 

Three phase and four wire380V/400V/415V±1%(Static State) 380V/400V/415V±3%Load0100%Change

Frequency

50 Hz±0.05%/60Hz±0.05%(The unit shock)

() Simultaneously with line input

(commercilal power status)

 

(Overload capacity)

130%10(Minute)  130-150%60(Second)

 

(Crest ratio)

31

THD

(Degree of distortion THD)

<3%(100%)Harmonic distortion of The Phase voltage main Wave(Linear load)

(Output waveform)

(Pure sine wave)

100%(100% Unbalanced load)

(Operate continuously)

(Power factor)

0.8-1(Lagging)

 

Battery

 

(Charge current)

6-30A

 

 

Display

LCD

 

(Big screen dot-maxtrix display operating statusmenu operationvoltagecurrentparametermodel)

LED

UPSUPS

(UPS openationrectification errorUPS error)

 

Port

(Communication port)

RS232/RS485

 

Surrounding

 

(temperature humidity)

0-40 90%

 