Product Detail
AVR, CPU control, LCD display, Metal, Sine wave, online,external battery

ModelMTT-10KVA~400KVA
Nominal capacity(KVA)10KVA~400KVA
Work principle Pure sine wave on line
Phase3phase(3 in,3 out)
Input power factor 0.8
RectifierNominal input voltage 220/380VAC 230/400VAC 240/415VAC
Range±25%
Nominal input frequency 50Hz±10% 60Hz±10%
Output ripple 2%
Soft start 0-100% 5sec
ChargeCharge mode Constant current to constant voltage,with temp compensation;with Auto change
Float Voltage 432VDC
Boost Voltage 464VDC
Temperature compensation voltage 3mV/1pcs
Charge current 0.1C(Automatically change follow the batteries)
Charge frequency 20% of Rated capacity
BatteryBattry Type Maintenance-free lead acid battery
Battery capacity 7-999AH settable(according to the capacity)
Battery number 32pcs 12V,or 192pcs 2V(Nominal voltage 384VDC)
InverterPhaseThree phase+N
CapacityRated capacity×0.8
Nominal voltage 220/380VAC 230/400VAC 240/415VAC
Output voltage stability ±1%(Stable load);±3%(fluctuant load)
Output frequency stability 50Hz/60Hz±0.5%
Creast factor 3:1
Output waveform distortion Sine wave,linear load3%;non-linear load5%
Dynamic characteristics Instant voltage±5%(from 0 to 100%),Instant recover time10mS
Unbalanced load voltage ±5%
Overload Protection 125%10m;150%1S;200%200ms
Efficiency95%(full load)
PhaseThree phase+N
BypassNominal voltage 220/380VAC 230/400VAC 240/415VAC
Transfer time 1mS(static switch with 0 transfer time)
Input protection Input voltage/frequency over limited;wrong phase;lack phase
ProtectionOutput protection Over current short circuit;factor low protection
Battery protection Over charge;over-discharge protection
Temperature protection Ambient over temperature protection;inverter over temperature protection
Hardware failure protectionAssistant power abnormal,breaker cut off,breaker overload,power components over current/over voltage
Working environment Temp:0-40,relative humidity 30%-90%;(a 1%decrease against 100metersrise.Altitude 4000m MAX)
Cooling-down method COMPULSIVE VENTILATION(with temperature control)
System Parameters Communication Interface RS232,RS485;optional SNMP card(for internet long distance monitor)
Redundancy function In series or N+1 parallel
Anti-surge capacity 10/700μS,5KV;8/20μS,20KA
Protection level IP21
Safety Performance Vin-n Vout-n 3000Vac,creepage3.5mA isolation resistance3M(500VDC)
Noise dB 48-55
Dimension(W×D×H)mm
Weight(Kg)200~1980

UPS(uninterrupted power supply)

Ads by Google

About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.