Technical data:
1, Max. operation pressure differential: 3.1MPa
2, Min. operation pressure differenetail:0.3MPa
3, Internal leakage: ≤4000ml/min(0.98Mpa)
4, Min operating voltage: 85% of rated voltage
5, Air tight test pressure: 4.15Mpa
6, Hydraulic strength:6.23MPa
7, Burst pressure: water pressure 20.8MPa
8, Allowable fluid temperature: -20°C~+120°C
9, Max. operating pressure: 4.15MPa
10, Voltage: AC: 220V~240V,,50/60HZ
11, Capacity: R410a 20Kw
12, Ambient humidity: <95%RH
13, Life: More than 20,000 cycles
14, Temperature rise of coil: <80K
15, Insulation resistance: >100MΩ
16, Noise: ≤45dB(A)
17, All parts should be approved by ROHS
18, Connection tube D Φ14*1, connection tube ESC Φ18*1
UL, CE, TUV certified 4-way reversing valve