Welcome to ECVERY
150mm/6" Electronic Digital Vernier Caliper(E009)
150mm/6" Electronic Digital Vernier Caliper(E009)
Supplier Info
[China Supplier]
Contact Person : Ms. Jin Mandy
Tel : 86-571-82430718
Fax : 86-571-56277060-1175
Product Detail
1.Measuring Range: 0-150mm/0-6in 2.Three-way measurements 3.certificate:CE 4.Display: LCD 5.Good Quality and low price

SPECIFICATIONS

1.caliper length : 23.6cm 

2.packing details:

QTY PER CTNN.W/G.WCTN SIZE
 50pcs 17/19kg48*27*32 cm

3.material: stainless steel(4cr13)

TECHNICAL SPECIFICATIONS

Outside Jaws:           Measure External Length

Inside Jaws:              Measure Internal Length

Measuring Range:       0-150mm/0-6in, 0~200mm/ 0~8 in

Resolution:                  0.01mm/ 0.0005in

Accuracy:                     ± 0.02mm/ 0.001in (<100mm)

                                    ±0.03mm/0.001in(>100-200mm)                                      

Repeatability:               0.01mm / 0.0005in

Max Measuring Speed: 1.5m/sec, 60in/sec

Measuring System:       Linear Capacitance measuring system

Display:                         LCD Screen

Construction Material:  Stainless Steel

Power:                          One alkaline lithium button cell battery 1.5v,TYPE LR44.

                                      Capacity-180MAH

Working  Temperature: 5°c-40°c/41 to 104 degree f

Note:                  Accuracy affected in environments exceeding 80% relative humidity.

•APPLICATIONS

1.Operation : slider can be removed only after the locking screw (#10) is loosened.

2.Basic measuring methods : 

1) loosen the locking screw

2) Press "ON " button, select sae or metric measurement by pressing "MM/INCH" button. 

    Pressing "MM/INCH" button after measurement will display the sae / metric conversion.

3)To reset display to zero, close external measuring jaws, then press "ZERO" button.

MAINTENANCE INSTRUCTIONS

1. Keep the calliper clean and dry (liquid can damage the slider)

2. Use a clean, dry cloth to clean all surfaces -do not use solvents or solvent based cleaners.

3. To save power, turn off the unit when not in use.

Avoid contact with electricty and /or electronic devices

BATTERY REPLACEMENT

Flashing display indicates low battery. To replace battery, remove battery cover by sliding cover in 

the direction indicated and replace battery with positive side facing out.

 TROUBLE SHOOTING

Falure

Cause 

Measure

Display flashes

Low battery

Replace battery 

Display does not change 

when slider is moved

System locked

Remove battery and replace 

after 30 seconds to reset system

Accuracy less than +/-0.001mm

Dirt in the sensor

Remove slider cover and its 

assembly, clean with compress 

air 5kgs/cm2

No display on LCD

1. improper battery 

position 

2. Low battery

1. Remove battery cover and 

check battery position 

2. Replace battery. 