Welcome to ECVERY
Anion Resin
Anion Resin
Supplier Info
[China Supplier]
Contact Person : Mr. Yang David
Tel : 86-552-6073156
Fax : 86-552-6073153
Product Detail
201x7 is a high capacity, shock resistant, gelular,Type I ,strongly basic anion exchange resin . Typical physical & Chemicalcharacteristics: Suggested Operating Condition: Hydraulic Properties: 
Product Name:  201x7 (Strong-Base Type I (Gel) Anion Exchange Resin)
Product Data Sheet
For Efficient Demineralibation Including Silica Removal201x7 is a high capacity, shock resistant, gelular,Type I ,strongly basic anion exchange resin supplied in the chloride or hydroxide form as moist, uniform, spherical beads. 201x7 is intended for use in all type of deionization systems and chemical processing applications.

Polymer Matrix Structure______________

Styrene Crosslinked with DVB

Physical Form and Appearance__________

Clear spherical beads

Whole Bead Count___________________

95% min.

Functional Groups____________________

R-N(CH3)3+

Ionic Form ,as shipped________________

CL

Total Exchange Capacity, CL- form, wet, volumetric__________________________

1.4 eq/l min.

Moisture Retention, CL- form___________

42-48%

Particle Size Range___________________

0.3-1.2mm,+1.2 mm <5%, -0.3 mm <1%

Swelling CL-→ OH-__________________

18-25%

Shipping Weight (approx.)_____________

700 g/l

Specific Gravity, moist CL- Form_______

1.09

PH Range, Stability___________________

0 - 14

Maximum TemperatureOH- Form__________________ CL- Form__________________

60°C (140oF) max. 80°C (176oF) max.

Minimum Bed Depth_________________

0.6m(24inches)

Backwash Rate______________________

50 to 75% Bed Expansion

Regenerant Concentration

2 - 6%

Regenerant Flow Rate ________________

2 to 8 BV/h (0.25 to 1.0gpm/cu/ft.)

Regenerant Contact Time _____________

At least 40 minutes

Regenerant Level ____________________

112 -300g/L (4 to 10 pounds/ cu/ft.)

Displacement Rinse Rate ______________

Same as Regenerant Flow Rate

Displacement Rinse Volume ___________

10 to 15 gallons/cu.ft.

Fast Rinse Rate ______________________

Same as Service Flow Rate

Fast Rinse Volume ___________________

35 to 60 gallons/cu.ft.

Service Flow Rate ___________________

10-25m/h (2 to 10 gpm/cu/ft.)

A. Pressure Drop: The graph above shows the expected pressure loss per foot of bed depth as a function of flow rate, at various temperatures. B. Backwash : After each cycle the resin bed should be backwashed at a rate that expands the bed 50 to 75 percent. This will remove anyforeign matter and reclassify the bed. The graph below shows the expansion characteristics of 201x7 in the sodium form.

Anion Resin