Ads by Google
AWS E8018-B2 Welding Rod / Welding Electrode
AWS 5.5 Class E8018-B2 / ASME SFA 5.5 Class E8018-B2
E8018-B2 welding electrode is for higher strength steels with tensile strengths greater than 80,000 pounds. The coating is specially formulated to resist moisture pick-up under conditions of high heat and humidity. This electrode offers resistance to moisture reabsorption which helps prevent hydrogen cracking and aids in elimination of starting porosity.
Type of Covering | Iron powder Low hydrogen Potassium | |||||||||
Welding Position | F,V, OH,H | |||||||||
Chemical Composition of Deposited Metal (%) | ||||||||||
Chemical Composition | C | Mn | Si | S | P | Cr | Ni | Mo | V | Cu |
Guarantee | 0.05-0.12 0.080 | ≤0.90 0.73 | ≤0.80 0.24 | ≤0.03 0.009 | ≤0.03 0.013 | 1.00-1.50 1.31 | — | 0.40-0.65 0.50 | — | — |
Mechanical Properties of Deposited Metal | ||||||||||
Test Item | Tensile Strengh Rm (MPa) | Yield point ReL (MPa) | Elongation A4 (%) | Akv1(J) | ||||||
Guarantee | ≥520 580 | ≥390 480 | ≥19 25 | — 25°C 180 | ||||||
Reference Current (AC≥70V or DC) | ||||||||||
Electrode Diameter(mm) | 2.0 | 2.5 | 3.2 | 4.0 | 5.0 | |||||
Welding Current(A) | 40-70 | 60-90 | 80-110 | 130-170 | 160-200 | |||||
Instructions | ||||||||||
1.The Electrodes must be baked under 350°C~380°C for an hour before Welding and used as soon as baking is completed. | ||||||||||
2.The stains on the weldments, such as rust, oil stains, moisture, etc., must be cleared away before Welding. | ||||||||||
3.When Welding, short arc must be used and stringer bead is suitable. | ||||||||||
Application | ||||||||||
Suitable for welding important structures made by 15CrMo steel, which work temperature below 520°C, such as boiler pipes, high pressure vessels, petroleum thermal cracking equirment, etc. Also it could weld cast steel of 30CrMnSi. |
Welding Rod / Welding Electrode AWS 5.5 E8018-B2