Welcome to ECVERY
RG187-High temperature cable
RG187-High temperature cable
Supplier Info
[China Supplier]
Contact Person : Ms. Jin huiyi
Tel : 0086-510-87499573
Fax : 0086-510-87491427
Product Detail
heat resistance, fire resistance, flexible, moisture resistance, corrosion resistance, fine, easy soldering

Flexible Fluoroplastic Insulation Small Diameter Coaxial Cable 

Application: applied in 3G mobile communications network construction, antenna, communications equipment, supercomputers, and also used as signal transmission line in mobile phones, laptops and medical equipment, etc.

Construction Specifications

Item                                                      Material                                   Diameter (mm)

1. Inner Conductor          Silver Plated Copper Clad Steel                   7*0.102

2. Dielectric                                            PTFE                                            1.60

3. Outer Conductor            Silver Plated Copper Braid                          2.05

4. Jacket                                                  FEP                                               2.67

Electrical Specifications

Capacitance (pF/m)                                               64

   Impedance (ohm)                                               75

   Velocity (%)                                                           70

   Maximum Operating Voltage (KV)                    1.2

   Maximum Work Frequency (MHz)                     400

Mechanical Specifications

   Minimum Bending Radius (mm)                                               10

   Operation Temperature (°C)                                             -55~+250

Attenuation (20°C, Sea Level)

Frequency (GHz)                Attenuation (dB/m)               

0.1                                                0.266                        

0.4                                                0.541                       

1.0                                                0.869                          

                     

                   

Note: Maximum attenuation value should be 110% of the nominal attenuation value.