SPECIAL FEATURES | ELECTRICAL SPECIFICATIONS | ||||||||
l UL879 Class 2 recognized, pass LPS | Input range | 90-264VAC Full range | |||||||
l Constant voltage design | Frequency | 47-63Hz | |||||||
l Universal AC input / Full range | Input Voltage | AC120V | |||||||
l Epoxy encapsulated with IP67 level | Output Voltage | DC12V/ DC24V | |||||||
l Withstand 300VAC surge input for 5 seconds | Output Current | 5A / 2.5A | |||||||
l Protections: Short circuit / Overload / Over voltage | Output power | 60W | |||||||
l Fully isolated plastic case | Inrush Current(max.) | 25°C cold star,60A at 230VAC | |||||||
l Cooling by free air convection | AC Current | ±1% | |||||||
l 100% full load burn-in test | Load Regulation | ±6% | |||||||
l Low cost, high reliability | Ripple&Noise | 1% | |||||||
l Suitable for LED lighting and moving sign applications | Effiency | 86% | |||||||
l 2 years warranty | Leakage Current | 0.25mA/240VAC | |||||||
ENVIRONMENTAL | Hold up Time | 500ms/230VAC,16ms/115VAC | |||||||
Operating Teperature: | -30 to 70°C | at full load | |||||||
De-rating:1%per °Cfrom50°C | Protection | Over-voltage, Over-current | |||||||
Humidity | 20%~90%(RH-Nondensing) | and short circuit | |||||||
Storage temperature | -40 to 80°C, 10-95%RH | protection: Auto-recovery | |||||||
Temp.conefficient | ±0.03% per °C(0~50°C) | SAFETY | |||||||
Vibration Frequency | 10~500Hz | UL | UL 879 class 2certified E333976 | ||||||
(2G 10min/ 1 cycle, period for 60min,each long X,Y,Z axes) | CE | Certified | |||||||
MTBF | 732Khrs min MIL-HDBK-217F(25°C) | ||||||||
EMC | Compliant to EN55022(CISPR22)class B. Compliant to EN61000-3-2,-3, | ||||||||
Compliant to EN61000-4,2,3,4,5,6,8,11;ENV55024,light industry level, Criteria A | |||||||||
NOTE | |||||||||
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. | |||||||||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf | |||||||||
parallel capacitor. | |||||||||
3. Tolerance : includes set up tolerance, line regulation and load regulation. | |||||||||
4. Derating may be needed under low input voltage. Please check the derating curve for more details. | |||||||||
5. The power supply is considered a component which will be installed a final equipment. The final equipment must be | |||||||||
re-confirmed that it still meets EMC directives. | |||||||||
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the | |||||||||
set up time. |
( function(){ var aBigImageSrc = [ 'http://i00.i.aliimg.com/photo/v2/328640124_1/60W_LED_power_supply.jpg' , 'http://i00.i.aliimg.com/photo/v2/328640124_2/60W_LED_power_supply.jpg' , 'http://i00.i.aliimg.com/photo/v2/328640124_3/60W_LED_power_supply.jpg' , 'http://i00.i.aliimg.com/photo/v2/328640124_4/60W_LED_power_supply.jpg' , 'http://i00.i.aliimg.com/photo/v2/328640124_5/60W_LED_power_supply.jpg' , 'http://i00.i.aliimg.com/photo/v2/328640124_6/60W_LED_power_supply.jpg' ]; var oProductShow = new AE.run.minisite.productShow(); oProductShow.init( { 'aImgSrc': aBigImageSrc } ); } )(); 60W LED power supply