The Automatic calorimeter is particularly suitable for testing material of low calorific value ... ensure the accuracy of the test.8. The volume of calorimeter tank is up to 60kg, and the water circulating adopts ... )HZ220±22VAC; (50±1)HZ220±22VAC; (50±1)HZ Automatic calorimeter (Normal type)
... :10-35 centigrade Temperature Resolution:0.001 centigrade OXYGEN BOMB CALORIMETER XRY-1A I. Main technical characteristics1. The instrument adopts self ... %;9. Power supply: AC 220V±5%, 50 Hz; OXYGEN BOMB CALORIMETER XRY-1A
... has good resistance of ambient temperature fluctuation.Feasible PlacementThis Calorimeter consists of Controlling unit and Temperature Controlling unit. ... term stability of water quantity.Simplified Water WayThe Calorimeter adopts 3 pumps and 3 valves.Comparing with ... analysis by these two bombs alternatively to use Calorimeter effectively.Stable Internal EnvironmentUser shall fill water through ...
... /T15765 and GB/T18429 3.Industry best Compressor Calorimeter It adopts the second refrigerant calorimeter method and gas flow method to test ... /T 9098, GB/T15765 and GB/T18429. second refrigerant Compressor Calorimeter
... and paraffin, etc. Purpose: XRY-1A Digital Display Oxygen Bomb Calorimeter is used to test calorie of solid and liquid, such ... : 15kJ/K Supportable Pressure: 20MPa Accuracy: ≤0.2% Oxygen bomb Calorimeter
... , such as coal, coke, petroleum and alcohol. Microcomputer Oxygen Bomb Calorimeter PurposeDetermining the caloric of solid and liquid, such as coal ... : ≤0.2%Oxygen bomb enduring pressure: 20MPa Microcomputer Oxygen Bomb Calorimeter
... ultrasonic flowmeter by adding a pair of temperature se ultrasonic calorimeter (ultrasonic heat meter; heat meter) is based on fixed ultrasonic ... flow of last 64 times of power on and ............ ultrasonic calorimeter(ultrasonic heat meter;flow meter)
... . Auto Temperature display 5. Auto Result Caculation SDACM-IIIb Bomb Calorimeter can test the calorific value of coal, coke, petroleum, food ... kit & Printer kit, USD600 Presentation in Indonesia High Accuracy Bomb Calorimeter
HQ-A series heat meter consists of calculator, flow meter and temperature sensors. heat meterTechnical specifications: 1) Temperature range: 4-95°C2) Difference in temperature range: 3-70°C3) Maximum display volume: 999999.999m³4) Maximum display heat energy: 999999.999kWh5) Accuracy: 3%6) Pressure class: 1.6MPa7) Maximum pressure loss: 0.025MPa Heat Meter
... real leading manufacture of handhold ultrasonic flow meter,water meter,calorimeter, TDS-100H handhold ultrasonic flow meter is a battery-powered ...
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.