Welcome to ECVERY
400W switching power supply (S-400-12)
400W switching power supply (S-400-12)
Supplier Info
[China Supplier]
Contact Person : Ms. Xu XiuQin
Tel : 86-0577-61755289
Fax : 86-0577-61755389
Product Detail
400W enclosed switching power supply 1.CE/ISO9001 certificate 2.100% full-load burn-in test for 6 hours 3.Samples avaiable Competitived price and high reliability 105oC Output capacitor AC input power suitable for the world High efficiency and low operation temperature Soft-start current can reduce the AC input impact effeciticly With short-circuit and overload protection Compact size, light weight 100% full-load burn-in test Installed with EMI filter, minimum wave

ModelS-400-9S-400-12S-400-13.5S-400-24S-400-27              S-400-48
DC output voltage9V12V13.5V24V27V48V
Output voltage range(Note:2)±1%±1%±1%±1%±1%±1%
Rated output current43A33A29A16.6A 14.8A8.3A
Output current range0-43A0-33A0-29A0-16.6A 0-14.8A0-8.3A
Wave and noise(Note:3)150mVp-p150mVp-p150mVp-p150mVp-p 200mVp-p200mVp-p
Inlet stability(Note:4)±0.5%±0.5%±0.5%±0.5% ±0.5%±0.5%
Load stability(Note:5)±0.5%±1%±0.5%±0.5% ±0.5%±0.5%
DC output power387W396W400W398.4WW 399.6W398.4WW
Efficiency78%83%85%85% 82%86%
Adjustable range for DC voltage±10%±10%±10%±10% ±10%±10%
Input current5.6A/115V 2.8A/230V
AC inrush current40A/230V
Leakage current<3.5mA/240VAC
Overload protection105%~135% Type: pulsing hiccup shutdown Reset: auto recovery
Over-voltage protection9.4-10.9V             13.8~16.2V15.5~18.2V18~21V27.6~32.4V33.7~39.2V 57.6~67.2V
High-temperature protectionERH3>=65~70°c Fan on, <=55~60°c Fan off,>=80~85°c, Cut off ouput(5~15V)~(24~48V)
Setup, rise , hold up time1.5s, 50ms, 20ms
Vibration10~500Hz, 2G 10min,/1cycle, Period for 60min, Each axes
Withstand voltageInput and output internal: 1.5KvAC, Input and enclosure:1.5KvAC, Output and enclosure:0.5KvAC
Working temperature and humidity -10°c~+60°c(Refer to output derating curve), 20%~90%RH
Weight1.1Kgs
Safety standardsUL 1950, EN60950
EMC standardsEN55022, EN100-4,2,4,5,6,8,11, IEC100-3-2

Note:                                                                                                                                                           

1. The testing condition for the paramenter above is: 230VAC input, rated load, 25°c 70% RH. Temperatuer.            

2. Error: include the setting error, line stability and load stability.(Note:5)                                                            

3. Wave test: adopting "A12" double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting.        

4. Inlet woltage stability test: when is over load, the lowest voltage of inlet is up to the highest voltage.                  

5. Load stability test: The load is from 0% to 100%

400W switching power supply (S-400-12)

Ads by Google

About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.