Welcome to ECVERY
35W switching power supply (S-35-5)
35W switching power supply (S-35-5)
Supplier Info
[China Supplier]
Contact Person : Ms. Xu XiuQin
Tel : 86-0577-61755289
Fax : 86-0577-61755389
Product Detail
1.35W switching power supply 2.CE Approved,100% burn-in test 3.Competitived price,shortest lead time 4.Samples availbale

1.        Competitived price and high reliability

2.        105oC Output capacitor

3.        AC input power suitable for the world

4.        High efficiency and low operation temperature

5.        Soft-start current can reduce the AC input impact effeciticly

6.        With short-circuit and overload protection

7.        Compact size, light weight

8.        100% full-load burn-in test

9.        Installed with EMI filter, minimum wave

 

ModelS-35-5S-35-12S-35-15S-35-24
DC output voltage5V12V15V24V
Output voltage rang(Note:2)±2%±1%±1%±1%
Rated output current7A3A2.4A1.5A
Output current range0-7A0-3A0-2.40-1.5A
Wave and noise(Note:3)75mVp-p100mVp-p101mVp-p100mVp-p
Inlet stability(Note:4)±0.5%±0.5%±0.5%±0.5%
Load stability(Note:5)±1%±0.5%±0.5%±0.5%
DC output power35W36W36W36W
Efficiency70%76%78%78%
Adjustale range for DC voltage +10,-5%+10%+10%+10%
Input current0.5A/115V 0.25A/230V
AC Inrush currentCold-start current 15A/115V 30A/230V
Leakage current<0.5mA/240VAC
Overload protection105%~150% Type: pulsing hiccup shutdown Reset: auto recovery
Temperature coefficient±0.03%/°c(0~50°c)
Setup, rise, hold up time200ms, 100ms, 30ms
Vibration10-500Hz, 2G 10min,/1cycle, Period for 60min, Each axes
Withstand voltageInput and output internal 1.5KVAC, Input and enclosuer 1.5 KVAC, Output and enclosuer 0.5 KVAC
Working temperature and humidity -10°c~+60 °c,Refer to output derating curve, 20%~90% RH
Store temperature and humidity -20°c~+85°c, 10%~95%RH
Weight0.4Kgs
Satety standardsMeet UL 1012 requirement(Not apply for the mark)
EMC standardsMeet FCC aprt 15 J Conduction class B
Note:                                                                                                                                                                                                                                                               1. The testing condition for the parameter above is: 230VAC input, rated load, 25°c 70%RH.Temperature.2. Error. include the setting error, line stability and load stability. (Note:5)3. Wave test: adopting "A12" double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting.4. Inlet voltage stability test: when is over load, the lowest voltage of inlet is up to the highest voltage.5. Load stability test: The load is from 0% to 100%.6. Total output canbe maximum Current, total load can not exceed the maximum output power.

35W switching power supply (S-35-5)

Ads by Google

About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.