We are manufacture of switching power supply from 1992.

 1.Low 

1.Low price and high reliability2.105°c output capacitor3.AC input power suitable for the world4.High efficiency and low operation temperature5.Soft-start current can reduce the AC input impact effectively6.With short-circuit and overload protection7.Compact size, light weight8.100% full-load burning test9.Installed with EMI filter, minimum wave

Model

Specification

S-35-5

S-35-12

S-35-15

S-35-24

DC output voltage

5V

12V

15V

24V

Output voltage error(Note2)

±2%

±1%

±1%

±1%

Rated output current

7A

3A

2.4A

1.5A

Output current rage

0-7A

0-3A

0-2.4A

0-1.5A

Wave and noise(Note3)

75mVp-p

100mVp-p

100mVp-p

100mVp-p

Inlet stability(Note4)

±0.5%

±0.5%

±0.5%

±0.5%

Load stability(Note5)

±1%

±0.5%

±0.5%

±0.5%

DC output power

35W

36W

36W

36W

Efficiency

70%

76%

78%

78%

Adjustable range for DC voltage

±10,-5%

±10%

±10%

±10%

AC input voltage range

85~132VAC/170~264VACselected by switch

Input current

0.85A/115V 0.45A/230V

AC impulse current

Cold-start current 18A/115V 36A/230V

Leakage current

<0.5mA/240VAC

Overload protection

105%~150% Type: current limiting;  Reset; auto recovery

Over-voltage protection

……

High-temperature protection

……

Temperature coefficient

±0.03%°c(0~50°c)

Setup rise hold up time

200ms,100ms,30ms

Vibration

10~500Hz,2G 10min./1cycle,Period for 60min,Each axes

Withstand voltage

Input and output interval:1.5KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC

Isolation resistance

Input and output interval,Input and enclosure,Output and enclosure:0500VAC/100M Ohms

Working temperature and humidity

-10°c~+60°c,20%~90%RH

Store temperature and humidity

-20°c~+85°c,10%~95RH

Overall dimension

129*98*38mm

Weight

0.4Kgs

Safety standards

MeetUL1012

EMC standards

……

Note:1.The testing condition for the parameter above is:230VAC input, rated load,25°c 70%Rh,Humidity2.Error,include the setting error, line stability and load stability.(Note:5)3.Wave test:adopting“A12”double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.5.Load stability test: The load is from 0% to 100%,others 60%.6.C2,3,11must be knocked down.