Welcome to ECVERY
Switching power supply
Switching power supply
Supplier Info
[China Supplier]
Contact Person : Mr. Shu Nicolas
Tel : 86-577-61728658
Fax : 86-577-62721271
Product Detail
We are manufacture of switching power supply from 1992.

 1.Low price and high reliability2.105°c output capacitor3.AC input power suitable for the world4.High efficiency and low operation temperature5.Soft-start current can reduce the AC input impact effectively6.With short-circuit and overload protection7.Compact size, light weight8.100% full-load burning test9.Installed with EMI filter, minimum wave

Model

Specification

S-15-5

S-15-12

S-15-24

DC output voltage

5V

12V

24V

Output voltage error (Note2)

±2%

±1%

±1%

Rated output current

3A

1.3A

0.7A

Output current rage

0-3A

0-1.3A

0-0.7A

Wave and noise(Note3)

50mVp-p

50mVp-p

100mVp-p

Inlet stability(Note4)

±0.5%

±0.5%

±0.5%

Load stability(Note5)

±1%

±0.5%

±0.5%

DC output power

15W

15.6W

16.8W

Efficiency

65%

68%

72%

Adjustable range for DC voltage

±10,-5%

±10%

±10%

AC input voltage range

85~132VAC/170~264VACselected by switch

Input current

0.5A/115V 0.25A/230V

AC impulse current

Cold-start current 15A/115V 30A/230V

Leakage current

<0.5mA/240VAC

Overload protection

105%~150%Type: current limiting ;Reset: auto recovery

Over-voltage protection

……

High-temperature protection

……

Temperature coefficient

±0.02%°c(0~50°c)

Setup rise hold up time

200ms,100ms,30ms

Vibration

10~500Hz,2G 10min./1cycle,Period for 60min,Each axes

Withstand voltage

Input and output interval:1.5KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC

Isolation resistance

Input and output interval,Input and enclosure,Output and enclosure:0500VAC/100M Ohms

Working temperature and humidity

-10°c~+60°c,20%~90%RH

Store temperature and humidity

-20°c~+85°c,10%~95RH

Overall dimension

99*97*35mm

Weight

0.3Kgs

Safety standards

Meet UL1012

EMC standards

……

Note:1.The testing condition for the parameter above is:230VAC input, rated load,25°c 70%Rh,Humidity2.Error,include the setting error, line stability and load stability.(Note:5)3.Wave test:adopting“A12”double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.5.Load stability test:The load is from 0% to 100%,others 60%.6.C2,3,11must be knocked down.

Switching power supply

Ads by Google

About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.